Animal endoscopes are precision optical equipment, and their cleaning, disinfection, and maintenance quality directly affect the safety of diagnosis and treatment and the lifespan of the equipment. The flexible endoscope has a complex structure and a slender lumen. If residual organic matter dries up after use, it may form a biofilm, which is difficult to completely penetrate with conventional disinfection. Therefore, immediate handling after operation is more crucial than thorough cleaning afterwards.

After each examination, the outer surface of the mirror body should be immediately wiped with enzyme containing cleaning solution, and the cleaning solution should be suctioned through the biopsy channel to prevent residual substances such as blood and mucus from drying up. Before immersing the mirror body in liquid, a leak test must be completed to confirm the integrity of the mirror body shell and pipeline, in order to avoid damage caused by liquid infiltration into the interior. Mirrors that fail leak detection should be discontinued and sent for repair.

The manual cleaning process requires disassembling detachable components and using a brush that matches the diameter of the channel to scrub all accessible tubes one by one. After scrubbing, rinse the residual cleaning agent with clean water. High level disinfection should be carried out according to the disinfectant type, concentration, and contact time specified in the equipment manual. After disinfection, rinse the pipeline with sterile water or filtered water to remove disinfectant residues. The drying process is often overlooked, but residual moisture may provide conditions for microbial growth. It is recommended to use pressure regulated medical compressed air to blow dry each channel, and if necessary, assist with alcohol flushing for drying.

When storing, the mirror should be hung vertically to ensure that it does not come into contact with the bottom of the cabinet or other mirrors. Removable valves should be removed and stored together with the mirror for traceability. Daily maintenance also includes regular checks on the surface of the insertion tube for scratches, whether the bending angle is normal, and whether the accessory channel is unobstructed. Establishing cleaning and disinfection records helps trace the processing status of each mirror.

This article is generated by AI and the content is for reference only. Please carefully discern